Cast- Iron Boilers
for fuel - oil or gas -fired blown air burners , combined with a vertical
storage vessel to be installed above or beside the boiler
- GG20 : boiler body
made of GG20 cast - iron
- operatetion with oil or gas - fired or oil - fired burner (SG 90 fuel oil only
)
- 23.5÷ 81 /KW : output range : 23.5÷ 81 KW
- central heating
- Central heating and domestic hot water with BOL 120 storage vessel only with
SG35 and SG46 boilers
- resistant to condensation
Technical Data:
|
Model |
|
|
SG23 |
SG35 |
SG46 |
SG58 |
SG70 |
SG80 |
|
Number
of sections |
|
|
2 |
3 |
4 |
5 |
6 |
7 |
|
Fuel |
Oil/Gas |
|
Max.
net output |
|
kw |
23.5 |
36.0 |
46.5 |
58.0 |
70.0 |
81.0 |
|
Max.output |
|
kw |
26.0 |
40.0 |
51.4 |
64.0 |
77.5 |
89.5 |
|
Efficiency at 100% |
|
% |
90.0 |
90.4 |
91.0 |
90.9 |
90.3 |
90.5 |
|
Efficiency at 30% |
|
% |
90 |
91 |
91 |
91 |
91 |
91 |
|
Flue
gas temperature** |
|
˚C |
205 |
200 |
195 |
210 |
220 |
220 |
|
Water
content |
|
L |
22.5 |
29.5 |
36.0 |
42.8 |
49.6 |
56.4 |
|
Max.
operating pressure |
|
bar |
4 |
4 |
4 |
4 |
4 |
4 |
|
Furnace |
D |
mm |
290 |
290 |
290 |
290 |
290 |
290 |
|
|
L |
mm |
270 |
400 |
530 |
660 |
790 |
920 |
|
Burner
connectionj |
|
mm |
110 |
110 |
110 |
110 |
110 |
110 |
|
Flue |
Ø |
mm |
130 |
130 |
130 |
150 |
1502 |
150 |
|
Flue
gas side load loss |
|
mbar |
0.25 |
0.25 |
0.27 |
0.30 |
0.35 |
0.40 |
|
Water
side load loss |
(At =
15k) |
mbar |
3 |
6 |
11 |
18 |
28 |
40 |
|
Flow
connection |
|
"G |
11/4 |
11/4 |
11/4 |
11/4 |
11/4 |
11/4 |
|
Return
connection |
|
"G |
11/4 |
11/4 |
11/4 |
11/4 |
11/4 |
11/4 |
|
Fill/drain connection |
|
"G |
1/2 |
1/2 |
1/2 |
1/2 |
1/2 |
1/2 |


120
Storage Vessel Technical Data
|
Model |
|
SG35 |
SG46 |
|
|
|
|
Temperature |
|
˚C |
- |
40-65 |
40-65 |
- |
- |
- |
|
Max.
pressure |
|
bar |
- |
8 |
8 |
- |
- |
- |
|
continuous delivery rate |
(At =
25k)*** |
L/min |
- |
16 |
16 |
- |
- |
- |
|
storage vessel content |
|
L |
- |
120 |
120 |
- |
- |
- |
* At maximum boiler
capacity : hot water temperature 80˚C - room temperature 20˚C
** Flue temperature
is measured withCO2 =13% for fuel oil , 10% for gas and with 80˚C boiler
temperature
*** With boiler outlet temperature = 80˚C and domestic hot water inlet temp =
10˚C
Control
Panel
Boiler control
panel :
- Main switch
- signal lamp
- Boiler thermometer
- Boiler Control thermostat
- Burner lock out signal lamp
- Manually reset safety thermostat
Storage vessel control panel :
- Summer / winter switch
- Boiler limit thermostat
- Storage vessel thermostat
- Storage vessel thermometer
Main
Technical Characteristics :
- High
efficiency boiler
- long - lasting GG20 cast-iron body
- hinged door opening to the right or left
- cast iron sections can be cleaned from the front
- Possibility of low-temperature operation
- Each section is hydraulically tested at 10 bar
- Assembled body is hydraulically tested at 6 bar
- Production cycle certified according to ISO 9002 Standards
- separate 120 liter capacity enameled steel storage heater
Delivery
Composition
SG boilers are
supplied on a single pallet and protected by a wooden crate . Delivery
includes :
- Boiler body complete with hinged door
- powder - painted steel shell
- Glass wool insulation
- Control panel
storage vessels are supplied on a single pallet and protected by a wooden crate
,
Delivery includes :
- 120 liter storage vessel
- powder - painted steel case
- connection kit with hoses , domestic hot water pump and fittings
Dimensions And Weight
|
Model |
SG23 |
SG35 |
SG46 |
SG58 |
SG70 |
SG80 |
|
Height |
H mm |
860 |
860 |
860 |
860 |
860 |
860 |
|
Width |
L mm |
600 |
600 |
600 |
600 |
600 |
600 |
|
Depth |
P MM |
445 |
555 |
685 |
805 |
915 |
1.045 |
|
Weight |
Kg |
120 |
155 |
200 |
245 |
285 |
325 |
|